Tripp Lite SU8000RT3U1TF uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA 7200 W 18 AC outlet(s)

Tripp Lite SU8000RT3U1TF uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA 7200 W 18 AC outlet(s)

SmartOnline 208/120V 8kVA 7.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, Bypass Switch

Trade Prices

Distributor Product SKU Stock Updated Price
BlueStar TRIPP LITE, EOL, REPLACED BY 9PX8KTF5, 8000VA SMART ONLINE DOUBLE-CONVERSION UPS, 8U RACK/TOWER, 208/120V NEMA OUTLETS SU8000RT3U1TF Register free see stock

Related Products

Description

Tripp Lite SU8000RT3U1TF 8000VA / 8kVA / 7200 watt online, double-conversion UPS system offers complete power protection for critical network applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking applications. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included detachable PDU with manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to connected equipment. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.
- Tripp Lite SU8000RT3U1TF 8kVA / 8000VA / 7200 watt on-line, double-conversion UPS system in 8U total rack/tower configuration (3U UPS power module, 3U external battery pack and 2U step-down transformer)
- Detachable PDU with manual bypass switch enables hot-swappable UPS power module replacement with no interruption in output power to connected networking equipment
- Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
- Hardwire input; 2 L6-30R, 4 L6-20R and 12 5-15/20R outlets
- Maximum installed rack depth of only 32.5 in. / 82.6cm inches
- Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise
- Double-conversion operation converts raw input from AC to DC, then re-synthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
- Maintains full-time sine wave output within 2% of 208/120V nominal at 60Hz during brownouts as low as 100V and overvoltages as high as 300V
- Expandable runtime is supported with optional BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH; BP240V1407C-1PH external battery packs
- Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
- Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs
- Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement
- PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted
- Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA (Network Shutdown Agent) for larger networks and PowerAlert NMS (Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices
- Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces
- HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
- Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces
- Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification
- Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module)
- Supports Emergency Power Off (EPO) via built-in interface
- Included rail kit supports 8U 19 inch rackmount installation in 4 post racks
- Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks
- Optional 2-9USTAND supports upright tower placement
- Front panel LEDs and LCD readout with scroll controls and password option supports visual monitoring of all major UPS functions and advanced UPS settings for charge level, nominal voltage selection, frequency conversion and other operational parameters
- LED / LCD display panel rotates for viewing in rackmount or tower configurations
- Network-grade AC surge and noise suppression
- Industrial mode option (factory preset) enables supports high current startup loads by momentarily switching to bypass mode in response to short duration overload conditions
- External battery packs are field replaceable and hot swappable

Specifications

Power
Output power capacity8 kVA
Output power7200 W
Input operation voltage (min)208 V
Output operation voltage (min)120 V
Output operation voltage (max)208 V
Maximum current50 A
Efficiency91%
Emergency Power Off (EPO)Yes
Power factor0.9
Crest factor3:1
Input frequency60 Hz
Performance
UPS topologyDouble-conversion (Online)
Number of input phases1
EMI/RFI noise filteringYes
Surge protectionYes
WaveformSine
Noise level60 dB
LED indicatorsYes
Audible alarm(s)Yes
Features
UPS topologyDouble-conversion (Online)
Output power capacity8 kVA
Country of originChina
Number of input phases1
Output power7200 W
Input operation voltage (min)208 V
Output operation voltage (min)120 V
Output operation voltage (max)208 V
Maximum current50 A
Efficiency91%
EMI/RFI noise filteringYes
Surge protectionYes
Emergency Power Off (EPO)Yes
WaveformSine
Power factor0.9
Crest factor3:1
Noise level60 dB
Audible alarm(s)Yes
Input frequency60 Hz
Ports & interfaces
AC outlets quantity18 AC outlet(s)
AC outlet typesNEMA 5–15, NEMA 5–20R, NEMA L6-20R, NEMA L6-30R
USB 2.0 ports quantity1
Serial ports quantity1
Battery
Battery recharge time6 h
Typical backup time at half load13.5 min
Typical backup time at full load5.5 min
Hot-swap batteryYes
Cold startYes
Design
Form factorRackmount/Tower
Country of originChina
Rack capacity8U
Product colourBlack
CertificationUL1778, CSA, NOM, FCC, Part 15 Category A
Cooling typeActive
LED indicatorsYes
Display typeLCD
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 50 °C
Operating altitude0 - 118110.2" (0 - 3000 m)
Technical details
Sustainability certificatesRoHS
Compliance certificatesRoHS
Cooling
Cooling typeActive
Weight & dimensions
Package width26" (660.4 mm)
Package depth41" (1041.4 mm)
Package height31.5" (800.1 mm)
Package weight402.1 lbs (182.4 kg)
Packaging data
Package width26" (660.4 mm)
Package depth41" (1041.4 mm)
Package height31.5" (800.1 mm)
Package weight402.1 lbs (182.4 kg)
Logistics data
Products per master (outer) case1 pc(s)
Master (outer) case width26" (660.4 mm)
Master (outer) case length41" (1041.4 mm)
Master (outer) case height31.5" (800.1 mm)
Master (outer) case gross weight402.1 lbs (182.4 kg)
Certificates
CertificationUL1778, CSA, NOM, FCC, Part 15 Category A