Tripp Lite PDUMH30HVATNET power distribution unit (PDU) 19 AC outlet(s) 2U Black

Tripp Lite PDUMH30HVATNET power distribution unit (PDU) 19 AC outlet(s) 2U Black

5kW Single-Phase ATS/Switched PDU, 208V (16 C13, 2 C19 & 1 L6-30R) 2 L6-30P Input Cords, 2U Rack-Mount

Trade Prices

Distributor Product SKU Stock Updated Price
D&H PDU Switched ATS 208V 30A 16 C PDUMH30HVATNETC Register free see stock
Ingram Micro SINGLE-PHASE SWITCH PDU 45495W
Synnex 5.76kW Single-Phase ATS/Switched PDU, LX Platform Interface, 208/240V (16 C13, 2 4730625

Related Products

Description

Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Highly reliable solid-state switching between primary and secondary inputs occurs in 1-5 milliseconds. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.
- 208V 30A Automatic Transfer Switch (ATS) / Switched PDU (Agency de-rated to 24A continuous)
- ATS features provide redundant power for critical network equipment with a single input power cord
- 2 digit display reports output power consumption in amps
- 2U horizontal rackmount form factor; 12.5 in. / 31.8 cm depth
- 19 built-in switched outlets (16 C13, 2 C19 & 1 L6-30R)
- Set of two 10 ft. / 3m NEMA L6-30P input cables support connection to separate PRIMARY and SECONDARY inputs
- ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
- ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)
- Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported
- On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
- Super-fast switchover between primary and secondary power sources occurs in 2-6 milliseconds
- Switched outlets and ethernet interface supports individual outlet control on a real-time or programmable basis and user-specified alarm notification thresholds for all reported site power conditions
- DHCP/Manual configuration support
- Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols
- Outlets are factory programmed for sequential turn-on at 250 millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction on startup
- Front panel LEDs confirm power availability on both input lines and for each output receptacle
- Included cord retention brackets keep vital network equipment plugged in and continuously powered
- TAA Compliant Version Available - Order Tripp Lite PDUMH30HVATNTAA

Specifications

Design
PDU typesSwitched
MountingHorizontal
Product colourBlack
CertificationUL 60950-1 (USA, Canada), Class A (Emissions), NOM (Mexico)
Rack capacity2U
Housing materialMetal
Ports & interfaces
Power plugNEMA L6-30P
AC outlets quantity19 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler, NEMA L6-30R
Features
LED indicatorsYes
Cable length118.1" (3 m)
CertificationUL 60950-1 (USA, Canada), Class A (Emissions), NOM (Mexico)
Ergonomics
LED indicatorsYes
Cable length118.1" (3 m)
Power
Nominal input voltage208 V
Maximum current30 A
Nominal output voltage208 V
AC input frequency60 Hz
Weight & dimensions
Dimensions (WxDxH)17.5 x 12.5 x 3.46" (445 x 318 x 88 mm)
Weight13.7 lbs (6.21 kg)
Width17.5" (444.5 mm)
Depth12.5" (317.5 mm)
Height3.5" (88.9 mm)
Package width16.8" (426.7 mm)
Package depth19.9" (505.5 mm)
Package height7.8" (198.1 mm)
Package weight19.4 lbs (8.8 kg)
Packaging data
Package width16.8" (426.7 mm)
Package depth19.9" (505.5 mm)
Package height7.8" (198.1 mm)
Package weight19.4 lbs (8.8 kg)
Operational conditions
Storage temperature (T-T)-15 - 50 °C
Operating altitude0 - 118110.2" (0 - 3000 m)
Technical details
Sustainability certificatesRoHS
Compliance certificatesRoHS
Logistics data
Products per master (outer) case1 pc(s)
Country of originTaiwan