Tripp Lite PDUMH15ATNET power distribution unit (PDU) 8 AC outlet(s) 1U Black

Tripp Lite PDUMH15ATNET power distribution unit (PDU) 8 AC outlet(s) 1U Black

1.4kW Single-Phase ATS / Switched PDU, 120V (8 5-15R), 2 5-15P, 100-127V Input, 2 12ft Cords, 1U Rack-Mount

Trade Prices

Distributor Product SKU Stock Updated Price
BlueStar TRIPP LITE, PDU SWITCHED ATS 120V 15A 5-15R 8 OUTLET 2 5-15P HORIZONTAL 1URM PDUMH15ATNET Register free see stock
D&H PDU8 NEMA 5-15R 15A & Web Card PDUMH15ATNETCN
Ingram Micro 1.4KW SINGLE PHASE ATS SWITCHED 42975F
Synnex 1.4kW Single-Phase ATS / Switched PDU with LX Platform Interface, 120V outlets ( 4247984

Related Products

Description

Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.
- 120V 15A Automatic Transfer Switch (ATS) / Switched PDU (Agency de-rated to 12A continuous)
- Provides a redundant A/B power option for non-redundant networking equipment with a single input power cord
- Switched PDU features enable programmable or real-time power control of individual outlets via built-in network interface
- Digital display continuously reports total output power consumption in amps
- 8 switched NEMA 5-15R outlets
- 1U horizontal rackmount form factor; 14.5 in. / 36.8 cm depth
- Set of two 12 ft. / 3.6m NEMA 5-15P input cables support connection to separate PRIMARY and SECONDARY power sources
- ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
- ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)
- Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported
- On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
- Super-fast switchover between primary and secondary power sources occurs in 2-7 milliseconds
- DHCP/Manual configuration support; Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols
- Compatible with optional ENVIROSENSE temperature monitor
- Outlets are factory programmed for sequential turn-on at 250 millisecond intervals as the PDU is first energized
- Front panel LEDs confirm power availability on both input lines
- TAA Compliant Version Available - Order Tripp Lite PDUMH15ATNETAA

Specifications

Design
PDU typesSwitched
MountingHorizontal
Product colourBlack
CertificationUL 60950-1, CSA, Class A, NOM
Rack capacity1U
Housing materialMetal
Ports & interfaces
Power plugNEMA 5–15P
AC outlets quantity8 AC outlet(s)
AC outlet typesNEMA 5–15R
I/O ports60950 (USA, Canada), Class A, NOM (Mexico), RoHS
Features
Cable length144.1" (3.66 m)
CertificationUL 60950-1, CSA, Class A, NOM
Ergonomics
Cable length144.1" (3.66 m)
Power
Nominal input voltage100-127 V
Maximum current15 A
Nominal output voltage100-127 V
AC input frequency60 Hz
Weight & dimensions
Dimensions (WxDxH)17.5 x 14.5 x 1.75" (444 x 368 x 44.4 mm)
Weight11 lbs (4.99 kg)
Width17.5" (444.5 mm)
Depth14.5" (368.3 mm)
Height1.75" (44.4 mm)
Package width20.8" (528.3 mm)
Package depth23.2" (589.3 mm)
Package height5.3" (134.6 mm)
Package weight16 lbs (7.26 kg)
Packaging data
Package width20.8" (528.3 mm)
Package depth23.2" (589.3 mm)
Package height5.3" (134.6 mm)
Package weight16 lbs (7.26 kg)
Operational conditions
Storage temperature (T-T)-15 - 50 °C
Operating altitude0 - 118110.2" (0 - 3000 m)
Technical details
Sustainability certificatesRoHS
Compliance certificatesRoHS
Logistics data
Products per master (outer) case1 pc(s)
Country of originTaiwan